MAIN FEATURES
- Measurement of Active, Reactive and Apparent electricity energy
- Maximum Demand Registration
- Load monitoring with Instantaneous Voltage, Current and Power Factor
- Load Profile recording
- TOU Control with flexible programming of up to 4 tariffs
- Internal real-time clock and calendar with battery backup
- Data storage in non-volatile memory
- Fully AMR (Automated Meter Reading) compatible
- Easily readable data indication on LCD display
+ MEASUREMENT AND REGISTRATION
- Energy: KWh, 4-Quadrant KVarh, KVAh
- Maximum Demand with date and time stamps
- Load profile recording
+ TOU (TIME OF USE) CONTROL
- Tariff switching Holidays, Weekend, & Seasons
- Number of tariffs 4 tariffs
- Programmable Holidays 24 for 10 years
- Number of seasons Up to 10 tariff seasons
- Number of daily profiles 4 daily profiles
- Maximum Demand 4 tariffs
+ DATA STORAGE
Energy
- Current [T1...T4, Tsum]
- Last 16 months [T1...T4, Tsum]
Max Demand
- Current [T1...T4, Tsum]
- Last 16 months [T1...T4]
+ LOAD PROFILE
- Integration period: 1, 5, 10, 15, 20, 30 or 60 min
- 420 days with integration period 60 min
- 6 independently programmable channels
+ EVENTS REGISTRATION
- Power outages with date & time
- Phase failure recording with time stamps and energy data
- Per-phase voltage-loss with time stamps
- Voltage-under/over with time stamps
- Per-phase current-loss with time stamps
- Current imbalance with time stamps
- Voltage qualification ratio
- Last meter programming date & time
- Reverse current flow and overload indication on LCD
+ COMMUNICATIONS
- Optical interface IEC 62056-21 (Optional *)
- Infrared interface
- RS 232/485
+ DISPLAY
- Cyclic data indication automatically or by keys
- Data indication on LCD during power outages
- 7 digit LCD
+ SECURITY
- 3 Levels of protection
+ RATINGS
- System 3P 3W, 3P 4W
- Accuracy class Class 0.2S/0.5S, Class 1
- Standard IEC 60687
- Reference voltage Un
3x57.7/100; 3x63.5/110
3x220/380; 3x230/400
Custom
- Reference current
Direct Connected 5(60)A, 10(120)A, 15(180)A
CT Operated 1.5(6)A, 5(20)A
- Start Current
Direct Connected 0.002 Ib
CT Operated 0.001 Ib
- Reference Frequency 50/60 Hz
- Power consumption:
In voltage circuit < 0.8 W; < 1 VA
In current circuit < 0.05 VA
- Temperature ranges:
Meter operating -30C to +70C
Meter storage -45C to +85C
Humidity: <= 95%
+ INTERNAL REALT-TIME CLOCK WITH BACKUP BATTERIES
- Time-keeping accuracy < 0.5 Sec / 24Hours
- Clock operating with battery > 15 years
- Clock synchronization through AMR software
+ Inputs and Outputs
- Electric pulse output(SO) 4 programmable channels
- LED test output 400 - 16000 imp/kWh
- Verifying pulse output kWh, kVarh
- 1Hz pulse output Duty cycle 50%
- Push-buttons Display browsing
+ CASE AND DIMENSION SIZES
- Case Materials Reinforced Polycarbonate
- UV Stabilized Cover Reinforced Polycarbonate
- Terminal Material Bakelite
- Insulation Protective Class II
- Dimensions (mm) 274 x 167 x 66
- Weight 1.8 Kg
- Water-proof IP51, IEC 529
+ ACCOMPANIED SOFTWARE
Bluestar Metering Program will be provided on request or
With meters purchasing. This Windows-based application
Can be used to program meter's parameters, read meter's
Data and load profile curves.
More Product Features